About the GE AZ41E12DAB
- 11,800 BTU
- Electric Heat
- 11.8 Energy Efficiency Ratio
- R-410A Refrigerant
- 3.5 Dehumidification Rate
- 420 Max. CFM
- Electronic Controls
- LED Display
Brand:
Installation:
Wall
BTU:
11,800 BTU
Max CFM:
420 CFM
Remote Included?:
No
Heat:
Electric Heat
Series:
Zoneline Deluxe
Height:
16"
Width:
42"
Depth:
20 7/8"
Volts:
230/208 Volts
Amps:
4.7 Amps
Energy Star Rated:
No
EER:
11.8
Selecting a GE air conditioner is not only good for the occupant and guests, it's a decision that will leave you resting comfortably as well. All GE air conditioners are engineered to give many years of dependable service with a full complement of standard features and a variety of exclusive GE features. They're designed for hassle-free installation and easy maintenance.
How to Choose a Room Air Conditioner
Compared to large capacity central units, room air conditioners have several advantages. The initial cost of a room air conditioning unit is significantly lower than the cost of central air. Because room air conditioners are designed for cooling small spaces, operating costs are reduced. And, room air conditioners can provide personalized temperature and humidity controls that central systems cannot.
Calculating Cooling Capacity
Cooling capacity is the critical factor in properly selecting a room air conditioner. Cooling capacity is measured in British Thermal Units (BTUs) and typical models will range in capacity from 5,000 BTUs to 28,500 BTUs.
Choosing an undersized unit will overwork the unit and it will not cool properly. Choosing an over-sized unit will cost more to buy and operate and it will not dehumidify properly.
We can help you to calculate capacity. Be prepared to provide specific information on:
- Room Dimensions
- A simple floor plan to show the location of doors and north-facing windows
- The number of people it will serve
- Sources of heat such as lamps, TV and appliances
- An explanation of what's above the intended room
- Your insulation provisions
Cooling Capacity by Room Size
Measure the length and width of the area to be cooled. Multiply the length by the width to determine square footage or square meters. Locate the room size in the chart below to select the appropriate BTUs. Then use the product information to select the unit for your room. When cooling rooms with uninsulated ceilings, great rooms, or southern or western sun exposures - step up to the next BTU size.
| Room Size | BTU | |
| Sq. Ft. | Sq. m | |
| 150 | 14 | up to 5,000 |
| 165 | 15 | 5,200 |
| 216 | 20 | 6,000 |
| 350 | 33 | 8,000 |
| 425 | 39 | 9,000 |
| 500 | 46 | 10,000 |
| 640 | 60 | 14,00 |
| 900 | 84 | 15,100 |
| 1,110 | 103 | 18,000 |
| 1,170 | 109 | 18,500 |
| 1,435 | 133 | 22,000 |
| 1,672 | 154 | 25,000 |
| 1,960 | 182 | 28,500 |
Air Conditioner Tips
Air flow - Keep air filters clean. Do not block air flow areas.
Roomside view - J-models feature concealed power cord storage, this eliminates excessive cord exposure when receptacle is located close to unit.
Wall Opening for RAB46/47/48 Cases
A finished opening of 26 1/8" x 15 3/4", clear of intrusions, is required. Keep clearance of 4" from side walls. Brick veneer or frame walls should have wood studding surrounding case to provide firm anchoring with screws. Case can be fastened directly to brick or block walls with screws sunk in lead expansion shields. NOTE: units should be caulked on all four sides of case to the building exterior to assure building integrity.
Key Features
- R-410A Refrigerant
- 11,800/11,600 BTUH Cooling Capacity
- 11.8/11.8 E.E.R.
- Electronic Touch Controls with LED Display
- 3.5 Dehumidification (pts/hr)
- 420/323 CFM Indoor Fan (High/Low)
- 75/38 Vent CFM
- Electronic 7-Step Temperature Limiting To Prevent
- Overcooling or Overheating of Room
- Heat Sentinel
- 29 Sound Transmission Class (STC)
- Warm Grey Beige
Manuals & Downloads
AZ41E12DAB Installation Instructions
AZ41E12DAB Quick Specs
AZ41E12DAB Use & Care Guide
Specifications
Features
Automatic Indoor Frost Control
Yes
Manual Vent Control
Hidden
Outdoor Vent Control
3 Positions
Central Desk Control Compatability
Standard
Auto Power Recovery
Yes
Rotary Compressor
Yes
Louvre Style
Reversible
Chassis Type
Slide-In
Temperature Limiting
Electronic 7-Step
Heat Sentinel
Yes
Sleep Mode
Yes
Discharge Grille
2-Position
Blower
Random Twist/Length Segment Tangential
Fan Motors
2
"SmartFan" Fan Cycle Control
Yes
Fan Only Settings
2-Speed, Hi/Low
Cool and Heat Only Settings
Hi/Low
Freeze Sentinel
Yes
Controls
Standard Microcomputer, Tactile Touch Pad Controls with LED
Universal Heaters
Yes
Solid-State Thermostat
Yes
Vent Control
3-Position
Filter Type
Rigid Frame, Slide-Out
Power and Ratings
Voltage
230/208
Power Factor
75/45
Cooling Watts
1,000/985
Cooling Amperes, F.L.
4.7/5.1
Cooling Amperes, L.R.
29.5
Sound Transmission Class (STC)
29
Wall Case Dimensions
RAB77A4 Width
42 1/8"
RAB71A Depth
13 3/4"
RAB71A Height
16"
RAB71A Width
42"
RAB77A4 Height
16 1/4"
RAB77A4 Depth
13 7/8"
Dimensions and Weight
Overall Width with Sleeve
42"
Overall Width (excludes sleeve)
40"
Overall Depth (excludes sleeve)
19 13/16"
Overall Height (excludes sleeve)
15 1/2"
Net Weight
105 lbs.
Overall Height with Sleeve
16" (RAB71A); 16 1/4" (RAB77A4)
Overall Depth with Sleeve
20 7/8" (RAB71A); 21" (RAB77A4)
Features
Type
Wall
PTAC
Yes
Remote Control Included
No
Control Type
Digital
Chassis Type
Thru the Wall
Wall Sleeve Included
No
Cooling Capacity (BTU)
11,800 BTU
Maximum Cooling Amps
4.7 Amps
Maximum Cooling Watts
1,000 Watts
Heat
Electric Heat
CFM Room Circulation
420 CFM
Energy Efficiency Rating
11.8
Product Information
Brand
GE
Model
AZ41E12DAB
UPC
084691208181
Series
Zoneline Deluxe
Wall Opening Dimensions
RAB77A4 Cutout Height
16 1/2" min.
RAB77A4 Cutout Width
42 3/8" min.
RAB71A Cutout Height
16 1/4" min.
RAB71A Cutout Width
42 1/4" min.
Dimensions
Width
42 Inch
Depth
20 7/8 Inch
Height
16 Inch
Capacity
Cooling BTUH
11,800/11,600
Energy Efficiency Ratio (EER)
11.8/11.8
Dehumidification Rate
3.5 pts./hr.
Performance
Temperature Range
60 - 85 degrees F
Vent CFM (Full Open/Partial Open)
75/38
CFM, Indoor Fan Low
323
CFM, Indoor Fan High
420
Refrigerant Type
R-410A
Voltage
230/208
Technical Details
Energy Star Rated
No
CEE Rating
Not Available
ADA Compliant
No
Voltage
230/208 Volts
General
Manufacturer
GE
Learning Center
Related Articles
More from GE
Need Assistance?